Regulatory guidance · November 2026
By
, Nelson Team
November 19, 2026
TL;DR
Alberta Tier 1 applies when the site fits the generic assumptions. Check land and water use, the soil layer that governs migration and the applicable exposure pathways.
Check whether Tier 1 assumptions hold. Nearby surface water, unusual ground conditions or a more sensitive use can change the assessment. Use Tier 2 where the framework requires it.
Verify what closure requires. A comparison with guideline values is one part of the evidence. Delineation, confirmatory sampling and the applicable closure process still matter.
An Alberta Tier 1 comparison can look straightforward on a spreadsheet. There is a laboratory result, a guideline and a column for exceedances. The harder work comes before any of that. Which land-use category applies? Which soil layer governs migration? Does the site behave the way the guideline assumes? A clean-looking table can send a project in the wrong direction if those questions are still open.
The Alberta Tier 1 Soil and Groundwater Remediation Guidelines provide generic values for sites that fit the province’s land-use and exposure assumptions. As of 19 November 2026, Alberta lists the June 2024 editions of both Tier 1 and Tier 2 as current. For a remediation certificate application, confirmatory results generally have to meet the edition in effect at the time of application. Alberta describes a narrow transition provision for the 2022 editions where written regulatory approval had already been granted before October 1, 2024. Check the applicable program if you are relying on historical data, because reclamation certificate applications have separate transition rules. [1], [2]
Tier 1 groups sites into five categories: natural area, agricultural, residential/parkland, commercial and industrial. Compare actual and applicable land uses with Alberta’s definitions. If a zoning bylaw or a public land decision allows a range of uses, evaluate those uses and apply the most sensitive applicable category. A former industrial yard being assessed for housing needs an assessment that addresses residential use. Its historical designation tells you about potential sources of contamination and may tell you little about who will be exposed after redevelopment. [2]
Check what happens at the property line. A neighbouring parcel may have a more sensitive use, and the guidelines include specific provisions to protect that use. Sections 3.2 and 5.1.1 describe a 30-metre buffer measured from the boundary of the more sensitive use. Within that buffer, check whether the more sensitive use yields lower values for vapour inhalation from soil or groundwater or for direct ecological contact with groundwater. Use the more protective values where the provisions require them. Where contamination has already migrated, assess the affected area against its own applicable land and water uses. [2]
Document water use separately. Identify nearby wells and aquifers that could supply drinking water, along with streams or other surface water bodies that could receive groundwater. Consider irrigation and livestock or wildlife watering where relevant. A building supplied by a municipal water main can still sit above an aquifer that meets the criteria for protection. Formal exclusion of the domestic use aquifer pathway has its own requirements under Tier 2 and Alberta’s related guidance. [1], [2]
Tier 1 provides values for fine- and coarse-grained soil. Alberta generally classifies soil as fine-grained when at least 50 per cent by mass passes a 75-micrometre sieve, and coarse-grained when less than 50 per cent passes. The particle-size test uses the fraction passing a 2-millimetre sieve. If more than 70 per cent of the sample by mass is retained on that sieve, classify the sample as coarse and assess whether very coarse materials make Tier 1 unsuitable. When particle-size information is insufficient, use the more conservative value for each substance. [2]
In layered ground, the most abundant soil may differ from the one controlling movement. A thin, continuous sand layer below the water table can transmit groundwater through a site otherwise dominated by fine-grained soil. A different layer may control vapour transport above the water table. Use borehole logs, particle-size data and hydrogeological evidence to explain which material governs the relevant pathways. If the data are too sparse to support that choice, identify what additional fieldwork would resolve it. [2]
Start with Table 1 for soil and Table 2 for groundwater. Table 3 covers qualifying subsoil cases for BTEX and petroleum hydrocarbon fractions. Table 4 addresses salinity. Check the relevant table notes, analytical units and depth conditions before applying any value. Use the pathway-specific appendices when the framework calls for them, such as evaluating a more sensitive neighbouring land use. Alberta’s general Tier 1 soil tables apply regardless of depth unless the guideline’s specific provisions allow alternatives, including certain subsoil petroleum hydrocarbon and salinity cases. Deeper samples still need to be assessed in relation to groundwater and any other relevant receptors. [1], [2]
A conceptual site model links the contaminant source to the ways it may reach people, water or ecological receptors. Under Tier 1, the generic value incorporates the pathways applicable to the land use and contaminant. Depending on the case, those pathways can include direct contact with soil, movement of vapour into a building or discharge of affected groundwater into surface water. Knowing which pathway drives the value helps you decide what to investigate next. [2]
Some conditions fall outside Tier 1 assumptions. Section 5.1.5 identifies, among other examples, a volatile source within 30 centimetres of a building foundation, unusually rapid transport through very coarse material and some fractured-bedrock settings. For aquatic-life protection, Tier 1 assumes at least 10 metres between where the soil or groundwater concentration is measured and the relevant discharge point at the surface water body capable of supporting an aquatic ecosystem. Within that distance, Alberta calls for a Tier 2 approach or, for groundwater, allows direct comparison to the corresponding freshwater aquatic-life guideline. Check the section for the conditions attached to those provisions, including seasonal water levels. [2]
Consider a former bulk fuel yard being converted to housing. A thin sand seam runs through the site and groundwater moves toward a creek. If the assessment uses a fine-grained industrial soil column simply because most borehole logs describe clay and the site formerly handled fuel, it can miss the relevant exposure scenario. Confirm the applicable land use, investigate the sand seam and determine which groundwater and aquatic-life provisions govern. Those findings may change the sampling design before anyone estimates a cleanup volume. [2]
Tier 2 can be appropriate when a generic assumption fails to represent the site or when sufficient evidence supports a permitted change to a guideline. Alberta describes two main ways to proceed: guideline adjustment within the framework and a site-specific risk assessment. A change can lead to a more stringent objective if a receptor is closer or exposure is greater than Tier 1 assumes. Any decision to exclude a pathway needs to meet the applicable exclusion criteria. A paved surface or the absence of a well in the immediate area, on its own, is a poor basis for assuming that an exposure pathway has been resolved. [1], [2]
Address active sources and demonstrated adverse effects even if sampled concentrations meet a guideline. If site conditions require ongoing barriers, restrictions or monitoring, discuss the exposure control requirements with the regulator and identify who will maintain the controls. [2], [3]
Ask what information would change the decision. If the generic number is driven by groundwater protection and the site has poorly defined hydrogeology, the useful next step is a better understanding of the groundwater system. If a source lies close to an occupied building, investigate the source and vapour pathway. For a site-specific risk assessment, check Alberta’s supplemental guidance and confirm the proposed approach and submission expectations with the responsible regulator. [1], [3]
A comparison to the applicable Tier 1 values shows where the sampled material meets or exceeds those values. The conclusion depends on the sampling coverage, analytical methods and reporting limits. An apparently compliant dataset can still leave a source undelineated or a receptor unassessed. Confirm the extent of the work and retain the rationale for the guideline selected for each contaminant and medium. Alberta’s assessment guidance sets out the reporting framework, including when a Record of Site Condition accompanies submissions. [1], [2], [4]
Under Alberta’s voluntary remediation certificate program, a limited certificate covers a defined area and a site-based certificate covers the entire site. Alberta also describes a Tier 2 Compliance Letter for an eligible area or site that meets Tier 2 objectives without remediation. That letter provides administrative closure. The protective regulatory closure associated with a remediation certificate is a separate outcome. Confirm which decision the project needs, the area it must cover and the evidence required to support the application. Alberta Environment and Protected Areas accepts limited and site-based certificate applications through its Digital Regulatory Assurance System (DRAS). For AER-jurisdiction sites, provincial guidance directs applicants to attach the certificate form to the OneStop Record of Site Condition. [5]
Before relying on a Tier 1 comparison for a dig limit or a closure submission, make sure someone reviewing the file can reconstruct the decision. They should be able to see which guideline edition you used, why the land use and soil texture apply, and what evidence supports the assumptions about water and other exposure pathways. That explanation is what makes the comparison defensible.
Government of Alberta, Soil and groundwater remediation, with official links to the current Tier 1 and Tier 2 editions and implementation dates https://www.alberta.ca/part-one-soil-and-groundwater-remediation
Government of Alberta, Alberta Tier 1 Soil and Groundwater Remediation Guidelines, June 2024, especially sections 3 and 5 https://open.alberta.ca/dataset/842becf6-dc0c-4cc7-8b29-e3f383133ddc/resource/b6b28b89-f0db-49c5-b3bd-6046943af610/download/epa-alberta-tier-1-soil-groundwater-remediation-guidelines-2024-06.pdf
Government of Alberta, Risk management https://www.alberta.ca/part-three-risk-management
Government of Alberta, Assessment and reporting https://www.alberta.ca/part-two-assessment-and-reporting
Government of Alberta, Regulatory closure https://www.alberta.ca/part-four-regulatory-closure
Browse the full remediation glossary.
Read Next
The Hub
Public PFAS, petroleum hydrocarbon and military site records for every state, province and territory.
Plus 14,737 release events reported across the United States and Canada in the last 12 months, spills, pipeline and rail incidents, fires and AFFF discharges, updated to 2026-08-16.
Stay Informed
Project milestones, regulatory developments, and technical briefs. One email at a time. No noise.