Back to Articles

Regulatory guidance · November 2026

PFAS and the changing landscape: What site owners should know

By

Nelson Staff

, Nelson Team

November 19, 2026

TL;DR

Landfill acceptance can change before excavation. For PFAS-contaminated soil, check the receiving landfill’s permit, acceptance policy and leachate arrangements.

Confirm before you dig. Get written acceptance for your waste and shipping window. Qualify a fallback and assign responsibility for rerouting.

Evaluate destruction early. Test representative source soil before the cleanup depends on an unproven treatment or a single destination.

When we look at PFAS-contaminated source soil, we start with what can be destroyed and what will still need to be managed. That is an environmental decision with a practical consequence for the owner. A cleanup that depends on landfill acceptance can lose its disposal route when a permit changes, a wastewater plant stops taking the landfill’s leachate or the operator tightens its criteria. That can happen while the rules at the original site stay the same. [1], [2], [3]

As of 19 November 2026, our review found no blanket prohibition on landfilling all PFAS-contaminated soil in Alberta, across Canada or at the U.S. federal level. There are real restrictions elsewhere. The European Union already requires destruction or irreversible transformation for certain waste containing listed PFAS at or above specified concentrations, subject to limited exceptions. In North America, some of the most consequential changes are occurring in the rules for what comes out of a landfill, particularly the water it collects. Site owners should account for both developments when choosing how to manage contaminated soil. [1], [2], [3], [4], [5]

What can change before a landfill ban

Start with the receiving facility’s permit and its written acceptance criteria. A permit sets the bounds of what a site may legally take. Operators can set tighter limits. North Bay, Ontario, offers a concrete example. The city accepts certain contaminated soils at Merrick Landfill, but the published criteria require PFAS non-detection for those soils. A project team that checked only whether the facility accepts contaminated soil would have missed the condition that matters. Ask which compounds the operator tests for and what laboratory reporting limits it requires. [6]

Then follow the leachate. At a landfill that sends this wastewater to an offsite plant, two facilities have to be able to manage the same PFAS problem. If the plant reduces what it will accept, the landfill may need alternative treatment or a different outlet. That can change which incoming loads it is willing to take, even if the rules at the landfill gate have never been amended. Check how the operator is managing that exposure before relying on a quote for a project that will run over several seasons. [1], [7], [8]

Alberta and Canada

In Alberta, start with the waste classification and the receiving facility’s authorization. The province separates hazardous, non-hazardous and inert landfills. Alberta’s Tier 1 soil and groundwater remediation guidelines serve a different purpose. They help assess contamination and remediation objectives at the site. Determine the disposal requirements for the excavated soil separately and get the operator’s decision in writing. Other provinces and territories generally administer their own facility authorizations. A route that crosses a provincial or national boundary can also trigger federal controls depending on the waste classification and the movement. [2], [3], [9], [10]

At the federal level, the Prohibition of Certain Toxic Substances Regulations, 2025 came into force on June 30, 2026. They tighten restrictions on specified PFAS and products containing them, including certain uses of firefighting foam, with transition provisions and exemptions. A separate federal consultation examined prohibiting other PFAS in firefighting foam, excluding fluoropolymers as defined in the proposal. Canada also proposed adding that broader class to Part 2 of Schedule 1 of the Canadian Environmental Protection Act. These measures address chemicals and their uses. For legacy soil from an airport or industrial fire-training area, the disposal decision still requires a separate review of the waste and destination. [3], [11], [12]

Reporting is changing as well. Canada added reporting requirements for 163 individual PFAS beginning with the 2025 National Pollutant Release Inventory reporting year, subject to the applicable reporting criteria. Environment and Climate Change Canada provides guidance for offsite landfills, including how to estimate PFAS quantities in leachate. That reporting is distinct from an acceptance limit. It brings more scrutiny to what facilities receive and where those compounds can end up. [7]

United States

The U.S. EPA’s 2026 interim guidance recommends permitted Subtitle C hazardous waste landfills where PFAS levels are relatively high and landfill disposal has already been selected. The document is guidance. EPA has separately stated its intent to revise landfill effluent guidelines to address PFAS discharges. Its regulatory agenda identified that action as long-term. An owner planning a multiyear cleanup should track developments with the proposed receiver and its wastewater outlet and check the actual requirements in effect when the soil moves. [1], [4], [13]

State laws can already change what a landfill has to do. Maine requires solid waste landfills that collect and manage leachate to incorporate PFAS testing into approved monitoring plans on a schedule approved by the state. A further law effective April 13, 2026 ties a required public-benefit finding for new or expanded state-owned solid waste landfills to treatment that reduces PFAS concentrations in leachate, among other conditions. The change concerns monitoring and treatment. It illustrates how requirements can reach a disposal route through the wastewater side of the operation. [5], [14]

There is also a distinction between cleanup liability and waste classification. The federal designation of PFOA and PFOS, including their salts and structural isomers, as hazardous substances under CERCLA took effect in 2024. The D.C. Circuit denied petitions challenging the designation in August 2026. Separately, EPA proposed adding nine PFAS to the list of hazardous constituents under the Resource Conservation and Recovery Act. That proposed listing is distinct from a federal hazardous-waste listing. When evaluating a disposal contract, determine the applicable waste classification and have the right people assess liability under the relevant cleanup law. [15], [16], [17]

The European Union already requires destruction in some cases

Article 7 of the EU Persistent Organic Pollutants Regulation generally requires the destruction or irreversible transformation of listed persistent organic pollutants in waste when the applicable Annex IV concentration limit is met or exceeded. Listed PFAS include PFOS, PFOA and PFHxS, with entries covering specified salts or related compounds. Below the Annex IV limits, other disposal or recovery may be possible under applicable EU law. For certain listed waste types, an authority can authorize other handling in exceptional circumstances under Annex V. The legal question turns on the specific compounds and concentrations, the waste category and the proposed destination. The EU limits are waste-management thresholds for that framework. [18]

The EU example shows what a destruction requirement looks like when written into law. For a site owner, it is also a reminder to retain enough compound-specific data to reassess a waste stream later. A report that provides only a single total PFAS number may leave the project team unable to make the comparison a future rule or receiving facility asks for. [18]

Plan for the terms you will have to meet on shipping day

Assign someone to recheck the route. Record the applicable rules and permit terms when you price the work. Ask the project lead to confirm them again before awarding the contract and before mobilization. For a long excavation, set a recheck at each major phase. Record who will notify the owner if the landfill changes its criteria, loses capacity or loses its leachate outlet. Make the written acceptance specific to the proposed waste profile and shipping window.

Put a second route in the budget. Suppose a former fire-training pad accounts for a meaningful share of the PFAS mass in a much larger excavation. Characterize that material separately so you can evaluate destruction for the source soil and assess the remaining material against its own requirements. Identify an authorized containment route for material that needs it, and qualify a second route before relying on either in the construction schedule. Compare the costs of haulage, treatment and verification under the available routes. In the tender, say who pays for resampling, stockpile management and rerouting if acceptance changes. A fallback works only if you can qualify it in time to keep construction moving.

Specify what a permanent outcome must demonstrate. Where the objective is to reduce PFAS mass, evaluate verified thermal destruction early, while there is still time to test representative feed and review the results. Ask how the process will account for target PFAS and relevant transformation products across treated soil, emissions and residuals. Check what the operator will monitor in production to show that the treatment stays within the conditions tested. A removal result for the soil alone leaves the fate of PFAS in the rest of the process unresolved. [4]

A site owner can make these decisions today without guessing what legislators will do next. Define the outcome the cleanup needs. Then ask what evidence the contractor will provide and what the project will do if its first destination stops taking the material. Those decisions belong in the scope before the first truck is booked.

References

U.S. Environmental Protection Agency, 2026 Interim Guidance on the Destruction and Disposal of PFAS, particularly the landfill and leachate discussion https://www.epa.gov/pfas/interim-guidance-destruction-and-disposal-pfas-and-materials-containing-pfas

Government of Alberta, Landfills, facility classes and approvals https://www.alberta.ca/landfills

Environment and Climate Change Canada, Recycling and disposal under the Prohibition of Certain Toxic Substances Regulations, 2025 https://www.canada.ca/en/environment-climate-change/services/management-toxic-substances/prohibition-certain-toxic-substances-regulations-2025/recycling-disposal-toxic-substances.html

U.S. Environmental Protection Agency, Fact Sheet for the 2026 Interim Guidance on the Destruction and Disposal of PFAS https://www.epa.gov/pfas/fact-sheet-2026-interim-guidance-destruction-and-disposal-pfas

Maine Revised Statutes, Title 38, section 1310-N, solid waste facility licences and leachate testing https://mainelegislature.org/statutes/38/title38sec1310-N.html

City of North Bay, Merrick Landfill contaminated soil acceptance requirements https://northbay.ca/city-services/garbage-recycling/landfill-operations/

Environment and Climate Change Canada, PFAS guidance for reporting to the National Pollutant Release Inventory https://www.canada.ca/en/environment-climate-change/services/national-pollutant-release-inventory/report/pfas.html

Michigan PFAS Action Response Team, Landfills Workgroup and industrial pretreatment observations https://www.michigan.gov/pfasresponse/Workgroups/Landfills

Government of Alberta, Soil and groundwater remediation, with current Tier 1 and Tier 2 editions https://www.alberta.ca/part-one-soil-and-groundwater-remediation

Environment and Climate Change Canada, Cross-border Movement of Hazardous Waste and Hazardous Recyclable Material Regulations overview https://www.canada.ca/en/environment-climate-change/services/managing-reducing-waste/cross-border-regulations.html

Environment and Climate Change Canada, PFAS and aqueous film-forming foam used in firefighting https://www.canada.ca/en/environment-climate-change/services/management-toxic-substances/list-canadian-environmental-protection-act/perfluorooctane-sulfonate/film-forming-foam-prohibition-toxic-substances.html

Government of Canada, PFAS class regulatory milestones, Schedule 1 proposal and Phase 1 consultation https://www.canada.ca/en/health-canada/services/chemical-substances/other-chemical-substances-interest/per-polyfluoroalkyl-substances.html

U.S. Office of Information and Regulatory Affairs, Landfills Effluent Guidelines agenda entry, RIN 2040-AG40 https://www.reginfo.gov/public/do/eAgendaViewRule?RIN=2040-AG40&pubId=202504

Maine Legislature, Public Law 2025, Chapter 651, sections 4 and 5 https://www.mainelegislature.org/legis/bills/getPDF.asp?item=3&paper=HP1383&snum=132

U.S. Environmental Protection Agency, Designation of PFOA and PFOS as CERCLA hazardous substances https://www.epa.gov/superfund/designation-perfluorooctanoic-acid-pfoa-and-perfluorooctanesulfonic-acid-pfos-cercla

U.S. Court of Appeals for the District of Columbia Circuit, Chamber of Commerce v. EPA, August 18, 2026 https://media.cadc.uscourts.gov/opinions/docs/2026/08/24-1193-2188689.pdf

U.S. Environmental Protection Agency, Proposal to list nine PFAS as RCRA hazardous constituents https://www.epa.gov/hw/proposal-list-nine-and-polyfluoroalkyl-compounds-resource-conservation-and-recovery-act

European Union, Regulation (EU) 2019/1021 on persistent organic pollutants, Article 7 and Annexes IV and V https://eur-lex.europa.eu/eli/reg/2019/1021/2026-01-01/eng

Read Next

Regulatory guidance•2026-11-19LNAPL remediation regulations: How to identify the requirements for your site

Regulatory guidance•2026-11-19Alberta Tier 1 soil and groundwater remediation guidelines: How to assess their applicability

Mobile thermal technology•2026Mobile thermal technology: configured for the material, brought to site

Back to Articles Main Page

The Hub / PFAS

See documented PFAS sites where you work

Public PFAS detections and cleanup standards for every state, province and territory, with open and closed sites.

Plus 14,737 release events reported across the United States and Canada in the last 12 months, spills, pipeline and rail incidents, fires and AFFF discharges, updated to 2026-08-16.

Open the Hub

Stay Informed

Get Nelson updates in your inbox

Project milestones, regulatory developments, and technical briefs. One email at a time. No noise.

Read Next

  • LNAPL remediation regulations: How to identify the requirements for your site
  • Alberta Tier 1 soil and groundwater remediation guidelines: How to assess their applicability
  • Mobile thermal technology: configured for the material, brought to site

More from Nelson

  • LNAPL remediation regulations: How to identify the requirements for your site
  • Alberta Tier 1 soil and groundwater remediation guidelines: How to assess their applicability
  • Mobile thermal technology: configured for the material, brought to site
  • How to use The Hub for contamination research
  • Navigator: a practical guide to remediation strategy
  • The Ground Truth: Warren Nelson's remediation newsletter
  • A new era of enlightenment
  • Value should be the final outcome
  • What’s next at Nelson
  • Why independent research matters more than anything
  • Over thirty years of permanent outcomes: a field review of Nelson’s project record
  • Petroleum-contaminated soil treatment in the US: build the plan around the fuel profile

Site Navigation

  • All Articles & Research
  • Thermal Remediation Capabilities
  • Project Case Studies
  • Remediation Glossary
  • About Nelson Environmental Remediation
  • Contact Nelson