Hexavalent Chromium Remediation Services: Chromium 6 Reduction and Cleanup

The oxidized, mobile, IARC Group 1 carcinogenic form of chromium — regulated at 10 μg/L in California drinking water — whose remediation is defined by in-situ chemical reduction to immobile, non-toxic Cr(III).

Also known as: Cr(VI), Cr VI, chromium 6, chromium(VI), chromate, dichromate.

Hexavalent chromium — Cr(VI) — is the oxidized state of chromium and the state that drives every regulatory action. It is water-soluble across a wide pH range, present as the chromate (CrO₄²⁻) or dichromate (Cr₂O₇²⁻) oxyanion, and mobile through virtually every aquifer matrix. IARC lists Cr(VI) as a Group 1 human carcinogen; California's Public Health Goal for Cr(VI) in drinking water is 0.02 μg/L, the lowest inorganic contaminant PHG on the books.

Trivalent chromium — Cr(III) — is the reduced state and is essentially non-toxic and immobile: it precipitates as chromium hydroxide (Cr(OH)₃) at circumneutral pH and does not migrate in groundwater. This valence difference is the entire remediation strategy. Reduce Cr(VI) to Cr(III), precipitate the chromium hydroxide in place, and the mobility and carcinogenicity are eliminated at the same time. The chromium atom stays in the aquifer, but the site closes.

The regulatory landscape is uneven and getting tighter. US EPA's total-chromium MCL is 100 μg/L (a stand-in for Cr(VI) plus Cr(III)); California adopted a Cr(VI)-specific MCL of 10 μg/L in 2024 with the state PHG at 0.02 μg/L; New Jersey, Minnesota, and North Carolina are moving toward Cr(VI)-specific standards. Canadian GCDWQ regulates total chromium at 50 μg/L.

Where it is found

Chrome-plating shops (hard chrome, decorative chrome). Chromate-based cooling-tower corrosion inhibitors (PG&E Hinkley). Leather-tannery yards. Wood-preservative operations (chromated copper arsenate). Chromite ore-processing residue (COPR) fill in Hudson County, NJ and Glasgow, Scotland. Aerospace and defense metal-finishing sites. Textile and pigment manufacturing.

Regulatory framing

Cr(VI) is regulated as its own analyte in a growing number of states and jurisdictions, not as part of total chromium. Cleanup criteria are set by drinking-water MCLs and, increasingly, by state-level Cr(VI)-specific values that are orders of magnitude tighter than the federal total-chromium standard.

JurisdictionCompoundStandard
US EPA (drinking water MCL)Total chromium (Includes Cr(VI) + Cr(III))100 μg/L
California (MCL)Hexavalent chromium (PHG at 0.02 μg/L)10 μg/L
New Jersey (proposed)Hexavalent chromiumUnder review
Health Canada (GCDWQ)Total chromium50 μg/L
US EPA RCRA (TCLP)Chromium (D007)5.0 mg/L leachate

How Nelson treats it

The Cr(VI) playbook is in-situ chemical reduction. Injected ferrous sulfate, calcium polysulfide, or zero-valent iron reduces the mobile, carcinogenic Cr(VI) to immobile, non-toxic Cr(III), which precipitates as chromium hydroxide in the aquifer. Full closure on the mobility axis without excavation.

In-situ chemical reduction with ferrous sulfate

Injected ferrous sulfate (FeSO₄) donates two electrons per iron atom, reducing Cr(VI) to Cr(III) which precipitates immediately as mixed Fe(III)/Cr(III) hydroxide. Fast kinetics, well-established at legacy chrome and chromate-cooling-water plumes. Requires pH control to keep the Cr(III) precipitated.

legacy chrome plumes, chromate cooling-tower releases, fast-turnaround remediation

In-situ chemical reduction with ferrous sulfate

In-situ chemical reduction with calcium polysulfide

Calcium polysulfide (CaSₓ) delivers reduced sulfur and calcium, reducing Cr(VI) to Cr(III) with the coproduction of elemental sulfur and Cr(III) sulfide. Longer-lived reducing capacity than ferrous sulfate — well-suited to source zones and plumes requiring durable reducing conditions.

large source zones, long-term plume management

In-situ chemical reduction with calcium polysulfide

Zero-valent iron (ZVI) permeable reactive barriers

Zero-valent iron trenches or injected micro-scale ZVI form permanent reactive barriers that reduce Cr(VI) migrating through the plume front. Long-lived (10–20 year design life) passive systems that anchor plume-cutoff strategies.

plume cutoff, downgradient property protection, long-term passive treatment

Zero-valent iron (ZVI) permeable reactive barriers

Ex-situ pump-and-treat with ferrous reduction

Pumped groundwater is dosed with ferrous sulfate in an above-ground reactor, reducing Cr(VI) to Cr(III) which is precipitated, flocculated, and filtered. Standard train for regulated discharge to sewer or surface water. Meets 10 μg/L Cr(VI) compliance.

regulated discharge, hydraulic containment, low-yield aquifers

Stabilization/solidification for COPR fill

Chromite ore-processing residue (COPR) is a legacy Cr(VI) source in Hudson County, NJ and comparable sites. Ferrous-amended cement stabilization reduces Cr(VI) in the fill matrix while binding chromium into a leach-stable monolith that passes TCLP for on-site containment.

COPR fill, large-volume Cr(VI) soil, brownfield redevelopment

Stabilization/solidification for COPR fill

Frequently asked questions

What is hexavalent chromium remediation?

Hexavalent chromium — Cr(VI) — is remediated by in-situ chemical reduction. Injected ferrous sulfate, calcium polysulfide, or zero-valent iron converts mobile, IARC Group 1 carcinogenic Cr(VI) to immobile, non-toxic Cr(III), which precipitates as chromium hydroxide in the aquifer. The metal stays in place but no longer leaches or presents a drinking-water risk. This is the standard closure pathway for legacy chrome and chromate-cooling-water groundwater plumes at industrial brownfields.

What is the difference between Cr(VI) and Cr(III)?

Cr(VI) — hexavalent chromium, chromate, or dichromate — is the oxidized state: water-soluble, mobile in groundwater, and an IARC Group 1 human carcinogen. Cr(III) — trivalent chromium — is the reduced state: essentially non-toxic (in fact, a trace nutrient), and immobile because it precipitates as chromium hydroxide at circumneutral pH. Cr(VI) remediation is the process of converting one to the other.

What is the California Cr(VI) MCL?

California adopted a state MCL for hexavalent chromium of 10 μg/L, taking effect in 2024. The state Public Health Goal is 0.02 μg/L — the lowest inorganic PHG on the books — which drives long-term cleanup targets even where the enforceable MCL sits higher. The federal US EPA MCL remains at 100 μg/L for total chromium (Cr(VI) + Cr(III)).

What is the PG&E Hinkley case?

The PG&E Hinkley case — the basis for the film Erin Brockovich — is the reference plume for chromate-based cooling-tower corrosion inhibitors leaking Cr(VI) into a rural drinking-water aquifer. The site remains under active remediation using in-situ chemical reduction and a long-term monitoring program. It anchored California's push for a Cr(VI)-specific drinking-water standard.

Related topics

  • Hexavalent Chromium (Cr(VI))
  • In-Situ Chemical Reduction (ISCR)
  • Zero-Valent Iron (ZVI)
  • Permeable Reactive Barrier (PRB)
  • Stabilization and Solidification (S/S)
  • Heavy Metals (Arsenic, Mercury, Chromium, Lead)
  • Arsenic
  • Mercury
  • Asbestos
  • Chlorinated VOCs (CVOCs)

References

  • US EPA — National Primary Drinking Water Regulations
  • California State Water Board — Hexavalent Chromium MCL
  • NJDEP — Chromium-6 Standards
  • Health Canada — GCDWQ
  • US EPA — TCLP Method 1311

Where Nelson delivers Hexavalent Chromium (Cr(VI)) remediation

  • Mixed-Waste Soil Remediation in the United States
  • Mixed-Waste Soil Remediation in Canada
  • Mixed-Waste Soil Remediation in Alberta
  • Mixed-Waste Soil Remediation in British Columbia
  • Mixed-Waste Soil Remediation in Ontario
  • Mixed-Waste Soil Remediation in Quebec
  • Mixed-Waste Soil Remediation in Washington State

More from Nelson

  • PFAS and the changing landscape: What site owners should know
  • LNAPL remediation regulations: How to identify the requirements for your site
  • Alberta Tier 1 soil and groundwater remediation guidelines: How to assess their applicability
  • Mobile thermal technology: configured for the material, brought to site
  • How to use The Hub for contamination research
  • Navigator: a practical guide to remediation strategy
  • The Ground Truth: Warren Nelson's remediation newsletter
  • A new era of enlightenment
  • Value should be the final outcome
  • What’s next at Nelson
  • Why independent research matters more than anything
  • Over thirty years of permanent outcomes: a field review of Nelson’s project record

Site Navigation

  • All Articles & Research
  • Thermal Remediation Capabilities
  • Project Case Studies
  • Remediation Glossary
  • About Nelson Environmental Remediation
  • Contact Nelson