Hydrocarbon contamination map

FL

State drilldown

Hydrocarbon contamination in Florida

Confirmed release counts, the cleanup backlog still carrying an open file, and how the standards in Florida decide when a petroleum site is finished.

Confirmed releases

32,002

Every release reported to the federal tank record

Still open

9,360

Assessment or cleanup not yet signed off

Closed, no further action

22,642 (71%)

Regulator has signed the file off

Open per 100,000 people

45.4

Backlog density, useful for comparing jurisdictions of different size

The backlog in Florida

9,360 releases are still open across 67 counties. 8,382 of them were reported before the year 2000 and remain unresolved. Age matters on these files. Older releases have had time to reach groundwater, move under buildings and pick up receptors that were not there when the tank failed.

Backlog scorecard

How far Florida has worked through its reported petroleum releases, by the decade the release was reported. A low closure rate in an old decade points to files that have resisted conventional treatment.

Reported releases closed
71.0%
24,804 of 34,940 on the record
Median age of an open file
35 yrs
Median report year 1991
Open and reported before 2000
8,382
3,889 of those predate 1990
Oldest open report year
1979
Earliest unresolved release on the federal record

Closure rate by reporting decade

Before 199064%

1990s73%

2000s82%

2010s59%

Read as: of every release first reported in that decade, the share now marked closed or no further action. Report dates come from the federal record. The date a file closed is not published federally, so closure is measured as current status, not elapsed time.

89

90

91

92

93

94

95

96

97

98

99

00

01

02

03

04

05

06

07

08

09

10

11

12

13

14

15

16

17

18

Still open

Closed or no further action

Releases by the year they were first reported, split by current status. Records without a reported date are excluded from this chart but counted in the totals above.

What was released

Not classified

10,067

Product classification on open releases only. A large share of state submissions carry no product code, which is why the not classified count is often the largest.

County

Open

Total reported

Open per 100k

Miami-Dade

1,025

3,550

37.9

Hillsborough

774

2,750

56.0

Orange

687

2,131

51.5

Pinellas

670

1,997

69.2

Duval

653

1,967

70.0

Broward

550

2,235

29.2

Palm Beach

414

1,883

28.7

Polk

317

1,409

47.9

Volusia

279

732

52.8

Brevard

254

741

43.9

Lee

227

760

31.5

Escambia

223

817

70.2

Leon

193

525

66.9

Marion

191

501

54.4

Manatee

163

470

43.3

Reported release events, United States

Every oil and chemical release in the United States is supposed to be called in to one federal number. These are those calls, newest first, covering pipelines, tanks and facilities, rail and highway hazmat, vessels, and firefighting foam discharges.

Filter reported material

Aug 16, 2026Cape Coral, FLVesselReached waterVessel, gasoline: automotive (unleaded). Cause reported as vessel sinking.

Aug 16, 2026Golden Oak/Lake Buena Vista, FLFixedReached waterWalt Disney World. Fixed, gasoline: automotive (unleaded). Cause reported as operator error.

Aug 15, 2026FLUnknown SheenReached waterUnknown Sheen, unknown oil. Cause reported as unknown.

Aug 15, 2026FLUnknown SheenReached waterUnknown Sheen, unknown oil. Cause reported as unknown.

Aug 14, 2026Debary, FLFixedFixed, oil, misc: motor and 2 other materials. Cause reported as other.

Aug 13, 2026FLVesselReached waterNaval Station Mayport. Vessel, oil-based paint. Cause reported as unknown.

Aug 13, 2026Fort Myers, FLStorage TankUsps. Storage Tank, oil, misc: motor. Cause reported as equipment failure.

Aug 13, 2026FLUnknown SheenReached waterUnknown Sheen, unknown oil. Cause reported as unknown.

Aug 13, 2026FLUnknown SheenReached waterUnknown Sheen, unknown oil. Cause reported as unknown.

Aug 12, 2026Alachua, FLFixedFixed, oil, misc: motor. Cause reported as dumping.

Aug 12, 2026Pensacola, FLVesselReached waterBorr Drilling. Vessel, hydraulic oil. Cause reported as equipment failure.

Aug 12, 2026Cape Coral, FLVesselVessel, oil: diesel. Cause reported as vessel sinking.

Notifications are initial reports made to the federal call centre. They are not verified release volumes and some are later found to be unsubstantiated. Counts read as reported events, not as confirmed sites. Source: National Response Center, United States Coast Guard, US federal government work, public domain. Reported oil and chemical release notifications, calendar years 2025 to 2026. Compiled 2026-08-22.

How the standards apply in Florida

Florida applies Cleanup Target Levels set in Chapter 62-777 F.A.C. for soil, groundwater and surface water.

Two numbers usually decide the scope of work on a petroleum file: the drinking water standard for benzene, because it drives groundwater cleanup, and the soil screening level for the land use in question, because it drives how much material has to be treated or removed. Both are set against the receptor, not the release volume.

Federal underground storage tank rules in 40 CFR 280 set the release reporting, site check and corrective action steps. States with approved programmes run their own version, which can be stricter but not weaker.

Closure is decided on a risk basis. The programme compares confirmed soil and groundwater concentrations against screening levels for the actual land use, receptors and exposure pathways, then either signs the file off or requires further work.

Regulator

Florida Department of Environmental Protection

Programme

Petroleum Restoration Program

Medium

Parameter

Threshold

Basis

Drinking water

Benzene

5 µg/L

US EPA National Primary Drinking Water Regulation, maximum contaminant level

Drinking water

Toluene

1,000 µg/L

US EPA National Primary Drinking Water Regulation

Drinking water

Ethylbenzene

700 µg/L

US EPA National Primary Drinking Water Regulation

Drinking water

Total xylenes

10,000 µg/L

US EPA National Primary Drinking Water Regulation

Soil, residential

Benzene

1.2 mg/kg

US EPA Regional Screening Level, residential soil, target risk 1E-6

Soil, industrial

Benzene

5.4 mg/kg

US EPA Regional Screening Level, industrial soil, target risk 1E-6

Public agency records, compiled by Nelson.

These are reference thresholds, not a substitute for the jurisdiction's current tables. Numbers change, and site specific criteria can be set higher or lower once land use, depth and receptors are confirmed. Always work from the agency source linked below.

Sources

Data not supplied by Nelson. Every figure comes from public regulator records published by the agencies cited. Nelson compiles, maps and links the records, and does not create, verify, adjust or own the underlying data. This hub is a free public resource published to share knowledge. Every figure traces to a government dataset a reader can download and re-check, the sources are listed in the methodology, and nothing here is gated behind a form. Dataset compilation copyright 2026 Nelson Environmental Remediation Ltd. All rights reserved. Source attribution required for reuse. Data licence and citation.

Florida Petroleum Restoration Program

US EPA UST Finder, source of the release counts on this page

US EPA Regional Screening Levels

US EPA National Primary Drinking Water Regulations

Download the underlying data

Back to the national map

Nelson has treated hydrocarbon impacted soil for more than thirty years, from gasoline and diesel through heavy fuel oil and refinery sludge. If a site in Florida needs a treatment path, our team can walk you through the options.

Other state drilldowns

ALAlabamaUnderground Storage Tank and Alabama Tank Trust Fund programme

AKAlaskaContaminated Sites and Storage Tank programme

AZArizonaUnderground Storage Tank and Voluntary Remediation programme

ARArkansasRegulated Storage Tanks Division

CACaliforniaUnderground Storage Tank Cleanup Fund and Low Threat Closure Policy

COColoradoPetroleum Storage Tank programme

CTConnecticutRemediation Standard Regulations and UST programme

DEDelawareTank Management Section and Site Investigation and Restoration

DCDistrict of ColumbiaUnderground Storage Tank Division

Contact

How can we help?

Project inquiries, technical consultation, or emergencies.

We respond to project inquiries within one business day.

Nelson Environmental Remediation

Head Office

30541 - 100 Avenue

Acheson (Edmonton), Alberta

Canada T7X 6L8

Phone

1.780.960.3660

Toll Free: 1.888.960.8222

Fax

1.780.962.6885

Email

Follow Us on LinkedIn →

More from Nelson

  • PFAS and the changing landscape: What site owners should know
  • LNAPL remediation regulations: How to identify the requirements for your site
  • Alberta Tier 1 soil and groundwater remediation guidelines: How to assess their applicability
  • Mobile thermal technology: configured for the material, brought to site
  • How to use The Hub for contamination research
  • Navigator: a practical guide to remediation strategy
  • The Ground Truth: Warren Nelson's remediation newsletter
  • A new era of enlightenment
  • Value should be the final outcome
  • What’s next at Nelson
  • Why independent research matters more than anything
  • Over thirty years of permanent outcomes: a field review of Nelson’s project record

Site Navigation

  • All Articles & Research
  • Thermal Remediation Capabilities
  • Project Case Studies
  • Remediation Glossary
  • About Nelson Environmental Remediation
  • Contact Nelson