WY
State Regulatory Brief
EPA Region 8
Federal MCL through Wyoming DEQ; F.E. Warren Air Force Base leads the inventory and logistics dominate the remedy choice.
Wyoming applies the federal drinking water rule. With the smallest population of any state and very long distances between facilities, the practical question in Wyoming is what a remedy costs to reach, not what standard applies.
Agency
Wyoming Department of Environmental Quality (DEQ), Water Quality Division
Primary Statute
Wyoming Water Quality Rules Chapter 12 incorporating 40 CFR 141 Subpart Z
Rule Adopted
Federal rule effective 25 June 2024
Compliance
2029-04-26
Context
Wyoming DEQ implements the federal PFAS rule and the state has adopted no additional standard. The federal MCLs of 4 ppt for PFOA and PFOS, 10 ppt each for PFHxS, PFNA and HFPO-DA, and a hazard index of 1 for the mixture took effect on 25 June 2024. Initial monitoring is due by 2027 and compliance by 26 April 2029.
F.E. Warren Air Force Base near Cheyenne is the state's most significant identified PFAS site, with fire training and flightline sources under federal investigation. Municipal airports and fire service training grounds across the state used the same foam, and the energy sector adds fire suppression at gas processing and refining facilities.
Every remedy question in Wyoming runs into distance. The nearest facility willing to accept PFAS-impacted material may be in another state, and acceptance criteria can change while a project is running. That makes any approach that depends on hauling material fragile, and it makes treatment at the site the more predictable option.
Numbers
Compound
Wyoming
Federal (2024 NPDWR)
Note
PFOANo state MCL4 pptFederal MCL controls, compliance 26 April 2029
PFOSNo state MCL4 pptFederal MCL controls
PFHxSNo state MCL10 ppt
PFNANo state MCL10 ppt
HFPO-DA (GenX)No state MCL10 ppt
MixtureNo state valueHI ≤ 1PFHxS, PFNA, HFPO-DA and PFBS combined
Energy sector fire suppressionNot separately regulatedNot separately regulatedFoam systems at processing and refining facilities are a source category
ppt = parts per trillion (ng/L). Where a state number is stricter, the state number controls; where the federal number is stricter, the federal number controls for public water systems.
History
2016-05EPA issues the 70 ppt lifetime health advisory for PFOA and PFOS combined, the first national number utilities worked to.
2019-2024F.E. Warren Air Force Base PFAS investigation proceeds through the federal restoration programme.
2021-10EPA publishes the PFAS Strategic Roadmap, committing to a drinking water rule, CERCLA designation and effluent guidelines.
2023-01UCMR 5 monitoring begins, putting 29 PFAS analytes into routine sampling at large and selected small systems.
2023-2025UCMR 5 monitoring gives Wyoming its first broad occurrence dataset.
2024-04-10EPA finalises the PFAS National Primary Drinking Water Regulation, 89 FR 32532.
2024-06-25The federal rule takes effect in this state, with initial monitoring due by 2027 and compliance by 26 April 2029.
2026-05-18EPA proposes changes to parts of the 2024 rule. Those changes are not final, and the 2024 values remain the ones to plan against.
Case Docket
ongoing
Fire training areas near Cheyenne under federal investigation, with groundwater work and sampling of nearby wells where the gradient warrants it.
emerging
Fixed fire suppression at gas processing and refining facilities used fluorinated foam. These systems are not systematically inventoried, so the record usually sits with the operator.
ongoing
Foam testing at municipal airports left the same signature at a smaller scale, typically affecting private wells rather than public supplies.
Compliance
Site liability runs through the state voluntary cleanup or remediation programme and, where PFOA or PFOS are present, through CERCLA following the 2024 hazardous substance designation.
Federal facilities work under CERCLA and the Defense Environmental Restoration Program, so the schedule and the funding follow the military service rather than the state permit calendar.
Spent granular activated carbon, ion exchange resin and impacted soil move under the state solid and hazardous waste rules. No PFAS-specific waste listing applies, which makes the disposal facility's own acceptance criteria the practical constraint.
On site thermal treatment needs a state air authorisation. Applications carry better when they include stack testing evidence and destruction data from comparable PFAS work.
Wyoming DEQ's Voluntary Remediation Program is the route to a closure document, with PFAS handled on a risk basis.
Disposal capacity within the state is limited, so a remedy plan should name the receiving facility and its acceptance criteria rather than assuming availability.
Obligations
Initial monitoring for all 6 regulated PFAS is due by 2027, quarterly for surface water systems and for groundwater systems serving more than 10,000 people, with reduced schedules available once results are consistently low.
Compliance is measured on a running annual average at each entry point to the distribution system, so a single quarter above the MCL can be carried by later clean quarters and a single clean quarter cannot rescue a bad year.
Public notice and reporting in the Consumer Confidence Report start once a system is in violation, and utilities that wait until 2029 to find out lose the years they would need to design and build treatment.
Laboratories must run EPA Method 533 or 537.1 for compliance samples. Site investigation work commonly uses Method 1633 for the wider analyte list in soil, sludge and wastewater.
Where the receptors are private wells, sampling has to be organised voluntarily. No rule requires it and no agency will schedule it automatically.
FAQ
Data not supplied by Nelson. Every figure comes from public regulator records published by the agencies cited. Nelson compiles, maps and links the records, and does not create, verify, adjust or own the underlying data. This hub is a free public resource published to share knowledge. Every figure traces to a government dataset a reader can download and re-check, the sources are listed in the methodology, and nothing here is gated behind a form. Dataset compilation copyright 2026 Nelson Environmental Remediation Ltd. All rights reserved. Source attribution required for reuse. Data licence and citation.
Wyoming DEQ Water Quality Division
US EPA, PFAS National Primary Drinking Water Regulation (2024)
US Department of Defense, PFAS cleanup and AFFF transition reporting
US EPA, Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) results
See all 51 US jurisdictions in the PFAS Regulatory Tracker →
Contact
Project inquiries, technical consultation, or emergencies.
We respond to project inquiries within one business day.
Nelson Environmental Remediation
Head Office
30541 - 100 Avenue
Acheson (Edmonton), Alberta
Canada T7X 6L8
Phone
Toll Free: 1.888.960.8222
Fax