A family of thousands of synthetic fluorinated organics — including PFOA, PFOS, GenX, PFHxS, and AFFF constituents — defined by C-F bonds that resist conventional treatment and require destruction technologies to close a site.
Also known as: per- and polyfluoroalkyl substances, perfluoroalkyl substances, PFAS chemicals, forever chemicals, fluorosurfactants.
PFAS, or per- and polyfluoroalkyl substances, are a family of more than 12,000 synthetic organic chemicals built around chains of carbon-fluorine bonds — the strongest single bond in organic chemistry. That bond strength is what gives PFAS their commercial value (they repel water, oil, and heat) and what makes them a remediation problem: the same C-F bonds that make PFAS useful also make them resistant to biodegradation, hydrolysis, photolysis, and every conventional oxidation and reduction pathway used on other organic contaminants.
The compound list the industry cares about is a small subset of the whole family. Long-chain legacy PFAS — perfluorooctanoic acid (PFOAUS EPA — PFOA Chemistry Summary) and perfluorooctane sulfonate (PFOSUS EPA — PFOS Chemistry Summary) — dominate the regulatory record and most legacy plumes. Short-chain replacements including PFBS, PFHxA, and GenX (HFPO-DA) are now regulated in parallel because the substitution program did not eliminate persistence. Precursors and polyfluorinated telomers convert to the regulated end-point acids over time; a TOP assayHoutz & Sedlak — TOP Assay Method is the standard characterization step because target analysis alone underestimates total PFAS mass.
PFAS resist every treatment approach that works on conventional contaminants. They cannot be biodegraded in a reasonable timeline. They are not oxidized by permanganate, persulfate, or Fenton's reagent at field-relevant conditions. Standard incineration temperatures are not sufficient to guarantee cleavage of C-F bonds; incomplete combustion produces PFAS-derived byproducts and can re-emit fluorinated species. Closure of a PFAS site therefore requires either indefinite containment or one of a small set of true destruction technologies that mineralize the C-F bond to fluoride ion.
PFAS contamination is anchored at facilities where aqueous film-forming foam (AFFF) was used or manufactured: military airfields, civilian airports, firefighter training grounds, and refinery/tank-farm foam-suppression systems. Manufacturing sources include fluorochemical plants, chrome-plating shops (mist suppressants), textile and paper coating facilities, and semiconductor sites. Land-application of biosolids and industrial wastewater has spread PFAS across agricultural soil. Landfill leachate is a persistent source because every PFAS-containing consumer product eventually reports to a landfill.
Regulatory pressure has stepped hard toward drinking-water enforcement. The US EPA's April 2024 National Primary Drinking Water Regulation set enforceable Maximum Contaminant Levels for PFOA and PFOS at 4 ng/L each — parts per trillion — with additional MCLs for PFHxS, PFNA, GenX, and a mixture hazard indexUS EPA — PFAS National Primary Drinking Water Regulation (April 2024). Health Canada's PFAS objective in drinking water is 30 ng/L total PFASHealth Canada — PFAS Objective for Drinking Water (2024). Multiple US states (Michigan, New Jersey, California, New York, Washington) already enforce their own state-specific PFAS MCLs.
PFAS drinking-water standards are set in the parts-per-trillion range and are the tightest quantitative environmental limits in mainstream practice. Every closure standard, cleanup target, and destruction verification specification derives from these values.
| Jurisdiction | Compound | Standard |
|---|---|---|
| US EPA (NPDWR, 2024) | PFOA (MCL) | 4.0 ng/L |
| US EPA (NPDWR, 2024) | PFOS (MCL) | 4.0 ng/L |
| US EPA (NPDWR, 2024) | PFHxS (MCL) | 10 ng/L |
| US EPA (NPDWR, 2024) | GenX (HFPO-DA) | 10 ng/L |
| US EPA (NPDWR, 2024) | Hazard Index (mixture) | 1.0 (unitless) |
| Health Canada | Total PFAS (objective) | 30 ng/L |
| Michigan (EGLE) | PFOA (MCL) | 8 ng/L |
| New Jersey (NJDEP) | PFNA (MCL) | 13 ng/L |
| Stockholm Convention (Annex A) | PFOS, PFOA, PFHxS | Elimination listing |
PFAS remediation is a two-stage decision: concentrate the mass, then destroy it. Nelson pairs a concentration step tuned to the matrix with a destruction technology validated for the PFAS list at that site.
Water above 374 °C and 22 MPa becomes a supercritical fluid that dissolves oxygen and PFAS together and drives complete C-F bond cleavage to fluoride ion, CO₂, and water. Nelson's pilot-scale SCWO destruction achieves >99.99% removal of PFOA and PFOS with fluoride mass balance closure. Best for concentrated waste streams: AFFF, IX regenerant, GAC eluate, landfill leachate concentrate.
AFFF concentrate, IX regenerant, GAC eluate, landfill leachate concentrate
Supercritical water oxidation (SCWO)
Boron-doped diamond or mixed-metal-oxide anodes generate hydroxyl radicals and direct-anodic-oxidation pathways that cleave C-F bonds without adding chemicals. Runs cold, runs continuously, and scales with cell area. Best for medium-concentration streams where SCWO is oversized.
mid-concentration liquids, continuous treatment, on-site destruction
Electrochemical oxidation (EO)
Non-thermal plasma at the gas-liquid interface generates reactive species (hydrated electrons, hydroxyl and hydrogen radicals) that reduce and oxidize PFAS in parallel. Effective on short-chain PFAS that resist other destruction routes. Best for polishing after primary destruction.
short-chain PFAS, polishing step, AFFF post-treatment
Sustained temperatures above 1100 °C with controlled residence time and post-combustion scrubbing (acid-gas scrubber for HF capture) mineralize PFAS-loaded solids: spent GAC, contaminated soil, IX resin. Verified by fluoride mass balance and product-of-incomplete-combustion (PIC) monitoring, not just target-analyte disappearance.
spent GAC, contaminated soil, IX resin, PFAS-loaded solids
Thermal destruction (high-temperature, controlled)
Concentration technology, not destruction. GAC removes PFAS from drinking water and groundwater by adsorption; spent carbon is a PFAS-loaded waste that goes to a destruction technology. Standard first stage for high-flow, low-concentration streams.
drinking water treatment, high-flow groundwater, polishing to non-detect
Granular activated carbon (GAC)
PFAS-selective anion-exchange resins concentrate PFAS from water into a small-volume regenerant stream that goes to destruction. Higher capacity and better short-chain performance than GAC for many matrices. Standard pairing with SCWO for AFFF-impacted groundwater.
AFFF groundwater, short-chain PFAS, regenerable systems
Total oxidizable precursor assay converts polyfluorinated precursors to their end-point PFCA acids so total PFAS mass is quantified before design. Target analysis alone systematically underestimates AFFF-impacted matrices. Nelson runs TOP as a design-basis step, not an afterthought.
AFFF site characterization, design-basis mass balance
PFAS stands for per- and polyfluoroalkyl substances — a family of more than 12,000 synthetic chemicals built around carbon-fluorine bonds. They are used in aqueous film-forming foam (AFFF), non-stick coatings, water-repellent textiles, food packaging, and firefighting. They resist conventional biological, chemical, and thermal treatment and are informally called 'forever chemicals' for that reason.
PFAS groundwater treatment is a two-stage process: a concentration step (granular activated carbon or PFAS-selective ion-exchange resin) removes PFAS from the water, and a destruction step (supercritical water oxidation, electrochemical oxidation, plasma, or high-temperature thermal treatment) mineralizes the concentrated PFAS to fluoride ion. Adsorption alone does not destroy PFAS — it moves the mass to a solid that must then be destroyed.
Yes. Supercritical water oxidation, electrochemical oxidation, plasma destruction, and controlled high-temperature thermal treatment above 1100 °C with acid-gas capture will cleave the C-F bond and mineralize PFAS to fluoride ion, CO₂, and water. Verification requires fluoride mass balance and monitoring for products of incomplete combustion, not just disappearance of target PFOA/PFOS.
The 2024 National Primary Drinking Water Regulation set enforceable Maximum Contaminant Levels of 4 ng/L for PFOA and 4 ng/L for PFOS, 10 ng/L each for PFHxS, PFNA, and GenX (HFPO-DA), and a Hazard Index of 1.0 for mixtures. These are among the strictest quantitative drinking-water standards in force globally.
Not reliably at standard hazardous-waste incinerator conditions. PFAS destruction requires sustained temperatures above about 1100 °C with controlled residence time, post-combustion scrubbing to capture hydrogen fluoride, and verification by fluoride mass balance plus products-of-incomplete-combustion monitoring. Uncontrolled combustion can produce shorter-chain PFAS byproducts and re-emit fluorinated species.
AFFF is aqueous film-forming foam, the fluorinated firefighting foam used at military airfields, civilian airports, refineries, and firefighter training grounds since the 1960s. AFFF contains a mixture of PFAS surfactants and polyfluorinated precursors. Every training discharge, every fire response, and every foam-system test released AFFF to soil and groundwater, and those legacy releases are the largest driver of PFAS groundwater plumes today.
Send the matrix, the volume, and the criteria you have to meet. Nelson comes back with the treatment route, what a pilot on your feed would need to confirm, and the verification package a regulator will accept. Thermal destruction of PFAS is pilot-validated, with Nelson selected for the NATO Science and Technology Organization PFAS test bed.