TCE and PCE Cleanup Services: Reductive Dechlorination to Ethene

Man-made chlorinated aliphatic hydrocarbons — tetrachloroethylene (PCE), trichloroethylene (TCE), 1,1,1-trichloroethane (TCA), cis-1,2-DCE, and vinyl chloride — that formed the industrial degreasing and dry-cleaning solvent market for four decades and left the densest DNAPL groundwater plumes in North America.

Also known as: chlorinated hydrocarbons, chlorinated aliphatic hydrocarbons, CAHs, chlorinated ethenes, chlorinated ethanes.

Chlorinated solvents are a family of chlorinated aliphatic hydrocarbons built around one or two carbons with chlorine substitutions on the C-H bonds. The commercially important members are the ethenes — tetrachloroethylene (PCE) and trichloroethylene (TCE) — plus the ethanes 1,1,1-trichloroethane (TCA) and 1,2-dichloroethane, and their reductive-dechlorination daughters cis-1,2-dichloroethylene (cis-DCE) and vinyl chlorideUS EPA — Trichloroethylene (TCE) Fact SheetUS EPA — Tetrachloroethylene (PCE) Fact Sheet. From roughly 1940 to the late 1980s these solvents were the default degreasers for machined parts, semiconductor cleaning, dry cleaning, and industrial cold cleaning; the volume released to soil during that window is why chlorinated solvent plumes are the most common groundwater contamination in the developed world.

The physical property that makes chlorinated solvents a persistent groundwater problem is density: PCE at 1.62 g/mL, TCE at 1.46 g/mL, TCA at 1.34 g/mL. Released as a pure-phase liquid, chlorinated solvents sink through the water table as a dense non-aqueous phase liquid (DNAPLUS EPA — DNAPL Characterization and Remediation) until they reach a low-permeability confining layer, where they pool and dissolve into groundwater at parts-per-million concentrations — orders of magnitude above the ppb-level drinking-water MCLs. A small DNAPL release from a single degreaser drum can drive a 30-year, mile-long dissolved plume.

Chlorinated solvents also present a vapor-intrusion pathway that other groundwater contaminants do not: volatilization from shallow groundwater or vadose-zone soil into overlying buildings through preferential pathways in the foundation. Vapor-intrusion mitigation (sub-slab depressurization, vapor barriers) is now a standard component of a chlorinated-solvent site closure, alongside the source-zone and plume treatment technologies.

Where it is found

The signature chlorinated-solvent sites are dry cleaners (PCE), aerospace and defense manufacturing (TCE, TCA), semiconductor fabs (TCA, TCE), metal-parts degreasing shops (TCE, TCA), electroplating facilities (TCE), and military bases (TCE, PCE, TCA). Vapor-intrusion investigations at former industrial parcels routinely find residual chlorinated-solvent plumes decades after operations closed.

US EPA maximum contaminant levels are 5 μg/L for both TCE and PCE, 200 μg/L for 1,1,1-TCA, and 2 μg/L for vinyl chlorideUS EPA — National Primary Drinking Water Regulations. Canadian Council of Ministers of the Environment (CCME) groundwater guidelines for the protection of freshwater aquatic life are tighter for some daughtersCCME — Canadian Water Quality Guidelines. British Columbia CSR Schedule 3.1 sets water-use standards specific to drinking-water aquifers.

Regulatory framing

Chlorinated-solvent standards are driven by drinking-water carcinogen classifications. Vinyl chloride at 2 μg/L is the tightest of the group because it is a Class A human carcinogen and the terminal daughter of PCE→TCE→DCE→VC dechlorination — a stalled dechlorination pathway can accumulate vinyl chloride above the MCL even when parent PCE is below detection.

JurisdictionCompoundStandard
US EPA (drinking water MCL)TCE (trichloroethylene)5 μg/L
US EPA (drinking water MCL)PCE (tetrachloroethylene)5 μg/L
US EPA (drinking water MCL)1,1,1-Trichloroethane (TCA)200 μg/L
US EPA (drinking water MCL)cis-1,2-Dichloroethylene70 μg/L
US EPA (drinking water MCL)Vinyl chloride2 μg/L
CCME (freshwater aquatic life)TCE21 μg/L
BC CSR Schedule 3.1TCE (drinking-water aquifer)5 μg/L

How Nelson treats it

Chlorinated-solvent closure is a source-zone plus plume decision. Nelson selects the source-zone treatment (thermal, ISCR, or ISCO) by DNAPL architecture and lithology, then pairs it with a plume-scale bioremediation or MNA polish stage plus vapor-intrusion mitigation where the water table is shallow.

In-situ chemical reduction (ISCR) with ZVI

Zero-valent iron and sulfidated ZVI drive abiotic reductive dechlorination of PCE and TCE straight through to ethene without stalling at vinyl chloride. Injected as micro- or nano-scale slurries, or emplaced as a permeable reactive barrier (PRB). Best for medium-density source zones and plume intercept.

source-zone mass reduction, PRB plume intercept, shallow anaerobic aquifers

In-situ chemical reduction (ISCR) with ZVI

Service page

Enhanced reductive dechlorination (bioremediation)

Electron-donor injection (emulsified vegetable oil, lactate, molasses) plus bioaugmentation with Dehalococcoides cultures completes the PCE → TCE → cis-DCE → vinyl chloride → ethene pathway biologically. Slower than ISCR but cheaper per treated volume. Best for plume-scale treatment.

dissolved-phase plumes, long treatment windows, cost-controlled sites

Enhanced reductive dechlorination (bioremediation)

In-situ thermal remediation (ERH, TCH, steam)

Electrical resistance heating, thermal conductive heating, and steam-enhanced extraction volatilize DNAPL from source zones and drive it to vapor-recovery wells. The only source-zone technology that reliably removes >99% of DNAPL mass. Best when the source is well-defined and closure-driven.

DNAPL source zones, low-permeability lithology, closure-driven cleanups

In-situ thermal remediation (ERH, TCH, steam)

Service page

In-situ chemical oxidation (ISCO)

Permanganate for PCE/TCE, activated persulfate for the full chlorinated-ethene set including TCA. Fast mass reduction; watch for rebound as sorbed-phase mass back-diffuses. Best for medium-concentration dissolved plumes and hot-spot polish.

dissolved plumes, hot-spot polish, fast timelines

In-situ chemical oxidation (ISCO)

Monitored natural attenuation (MNA)

Native dechlorinating microbial community + geochemical evidence of ongoing dechlorination (parent-daughter ratios, dissolved gases, isotope fractionation) can close a plume without active treatment. Best downgradient of a source-zone treatment as the polish phase.

polishing after source treatment, low-mass distal plumes

Monitored natural attenuation (MNA)

Vapor-intrusion mitigation

Sub-slab depressurization systems and vapor barriers cut the volatilization pathway from shallow groundwater into overlying buildings. Standard component of a chlorinated-solvent closure on any site with a shallow water table and an occupied building.

occupied buildings over plumes, shallow water tables

Vapor-intrusion mitigation

Frequently asked questions

What are chlorinated solvents?

Chlorinated solvents are chlorinated aliphatic hydrocarbons — principally tetrachloroethylene (PCE), trichloroethylene (TCE), 1,1,1-trichloroethane (TCA), and their reductive-dechlorination daughters cis-1,2-DCE and vinyl chloride. They were the dominant industrial degreasers and dry-cleaning solvents from 1940 to the late 1980s and are the most common groundwater contaminant in North America.

How do you remediate a TCE plume?

TCE remediation is a source-zone plus plume decision. Source-zone DNAPL is treated with in-situ thermal remediation (ERH, TCH, steam), in-situ chemical reduction with zero-valent iron, or in-situ chemical oxidation with permanganate. The dissolved plume is polished with enhanced reductive dechlorination bioremediation and monitored natural attenuation. Vapor-intrusion mitigation is added on shallow-water-table sites with overlying buildings.

What is the US EPA MCL for TCE and PCE?

Both TCE (trichloroethylene) and PCE (tetrachloroethylene) have a US EPA drinking-water Maximum Contaminant Level of 5 μg/L. Vinyl chloride, the terminal daughter of the reductive-dechlorination pathway, has a tighter MCL of 2 μg/L because it is a Class A human carcinogen.

Why do chlorinated solvents form DNAPL?

PCE, TCE, and TCA have densities of 1.62, 1.46, and 1.34 g/mL respectively — all denser than water. When released as pure-phase liquid, they sink through the water table as dense non-aqueous phase liquid (DNAPL) and pool on low-permeability layers, dissolving slowly into groundwater at concentrations orders of magnitude above drinking-water MCLs. A small DNAPL release can drive a decades-long plume.

Can chlorinated solvents be biodegraded?

Yes, under anaerobic conditions. Dehalococcoides bacteria carry out reductive dechlorination of PCE → TCE → cis-DCE → vinyl chloride → ethene. Enhanced reductive dechlorination is the standard bioremediation approach, using electron-donor injection plus bioaugmentation to ensure the pathway completes to ethene rather than stalling at vinyl chloride.

Related topics

  • Chlorinated Solvents
  • Dense Non-Aqueous Phase Liquid (DNAPL)
  • Light Non-Aqueous Phase Liquid (LNAPL)
  • Vapour Intrusion
  • Sub-Slab Depressurization (SSD)
  • Vapour Barrier
  • In-Situ Chemical Oxidation (ISCO)
  • In-Situ Chemical Reduction (ISCR)
  • Zero-Valent Iron (ZVI)
  • Permeable Reactive Barrier (PRB)
  • Enhanced Reductive Dechlorination (ERD)
  • Electrical Resistance Heating (ERH)
  • Thermal Conductive Heating (TCH)
  • Steam Enhanced Extraction (SEE)
  • Soil Vapour Extraction (SVE)
  • Monitored Natural Attenuation (MNA)
  • Mass Flux and Mass Discharge
  • Membrane Interface Probe (MIP)
  • Conceptual Site Model (CSM)
  • Chlorinated VOCs (CVOCs)
  • DNAPL and LNAPL (Non-Aqueous Phase Liquids)
  • In-Situ Chemical Oxidation (ISCO)

References

  • US EPA — Trichloroethylene (TCE) Fact Sheet
  • US EPA — Tetrachloroethylene (PCE) Fact Sheet
  • US EPA — DNAPL Characterization and Remediation
  • US EPA — National Primary Drinking Water Regulations
  • CCME — Canadian Water Quality Guidelines
  • BC Contaminated Sites Regulation — Schedule 3.1

Where Nelson delivers Chlorinated Solvents (TCE, PCE, TCA, DCE, VC) remediation

  • Hydrocarbon and contaminated soil remediation in Alberta
  • Hydrocarbon and contaminated soil remediation in British Columbia
  • Hydrocarbon and contaminated soil remediation in Saskatchewan
  • Hydrocarbon and contaminated soil remediation in Ontario
  • Hydrocarbon Remediation in the United States
  • Hydrocarbon Remediation in Texas
  • Hydrocarbon Remediation in North Dakota
  • Hydrocarbon Remediation in Pennsylvania
  • Hydrocarbon Remediation in California
  • Hydrocarbon Remediation in Alaska

More from Nelson

  • PFAS and the changing landscape: What site owners should know
  • LNAPL remediation regulations: How to identify the requirements for your site
  • Alberta Tier 1 soil and groundwater remediation guidelines: How to assess their applicability
  • Mobile thermal technology: configured for the material, brought to site
  • How to use The Hub for contamination research
  • Navigator: a practical guide to remediation strategy
  • The Ground Truth: Warren Nelson's remediation newsletter
  • A new era of enlightenment
  • Value should be the final outcome
  • What’s next at Nelson
  • Why independent research matters more than anything
  • Over thirty years of permanent outcomes: a field review of Nelson’s project record

Site Navigation

  • All Articles & Research
  • Thermal Remediation Capabilities
  • Project Case Studies
  • Remediation Glossary
  • About Nelson Environmental Remediation
  • Contact Nelson